Backflow Preventers
Double Check
Valve Lead Free Sizes: 2-1/2” – 12” Apollo 4ALF-100 LBF Series
Double Check
Detector Assembly – Apollo DCDALF4A/ DCDA2LF4A Series
The 2-1/2” – 12” Double Check Detector Assembly shall be an Apollo Model DCDALF 4A or DCDA2LF 4A. The assembly shall be manufactured in America and carry a 5-year Apollo factory warranty. The TriForce™ center-stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by SS snap-in retainers (2-1/2” – 6”) or SS studs & nuts (8” – 12”). Access to the check valves shall be by an Apollo quick-connect SS coupling (2-1/2” – 6”) or grooved couplings (8” – 12”). The bodies shall be domestic SS in 22-1/2” – 8” sizes and FDA epoxy-coated ductile iron in 10” & 12” sizes. The assembly consists of a mainline double check valve with a Type 2 bypass (Type 1 optional) consisting of a lead free* single check (SCV) and meter bypassing the mainline second check to prevent backflow while accurately measuring all flows up to 2 gpm while the mainline 2nd check remains closed. Assemblies with the optional Type 1 bypass consist of a lead free* double check valve and meter which bypass both mainline checks and accurately meter all flows up to 2 gpm with the mainline checks closed. The Apollo lead free* ball valve test cocks shall have SS handles. The pressure drop across the assembly shall be documented by an independent laboratory. The assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are non-health hazards
Double Check Valve - Apollo DCLF 4SG / 4SG / 4S Series
The Apollo DCLF 4SG / 4SG / 4S Series Double
Check Valve is designed to prevent contamination of the potable water supply
due to back-siphonage or backpressure from substances that are non-health
hazards. The modular check valves have replaceable seats and reversible EPDM
seat discs. Grooved connections on an epoxy-coated ductile iron body allow for
easy connection to butterfly valves or gate valves (2-1/2” - 8”), flanged (10”
only).
Reduced
Pressure Detector Assembly - Apollo RPDALF4A / RPDA2LF4A Series
The 2-1/2” – 12” Lead Free Reduced Pressure
Detector Assembly shall be an Apollo Model RPDALF4A or RPDA2LF4A. The assembly
shall be manufactured in America and carry a 5-year Apollo factory warranty.
The TriForceTM center-stem guided check valves shall feature reversible
silicone rubber seat discs. The check valves shall be held in place by SS
snap-in retainers (2-1/2” – 6”) or SS studs & nuts (8” – 12”). Access to
the check valves and relief valve internals shall be by an Apollo quick-connect
SS coupling (2-1/2” – 6”) or grooved couplings (covers) and SS bolts (relief
valves) (8” – 12”). The bodies shall be SS in 2-1/2” – 8” sizes and FDA
epoxy-coated ductile iron in 10” & 12” sizes. The assembly is a mainline RP
with a Type 2 bypass consisting of a lead free* single check valve (SCV) and
meter bypassing the mainline second check to prevent backflow while accurately
measuring all flows up to 2 gpm with the mainline 2nd check remaining closed.
Assemblies with the optional Type 1 bypass consist of a lead free* RP and meter
which bypasses both mainline checks and accurately meters all flows up to 2 gpm
with both mainline checks closed. The Apollo ball valve test cocks shall have
SS handles. Both RP relief valves shall be positioned at the bottom of their
respective assemblies with separate center-access covers. The pressure drop
across the assembly shall be documented by an independent laboratory. The
assembly shall prevent contamination of the potable water supply due to back-siphonage
or back pressure from substances that are health or non-health hazards
Double Check
Valve Lead Free Sizes: 2-1/2” – 12” Apollo 4ALF-100 LBF Series
Double Check
Detector Assembly – Apollo DCDALF4A/ DCDA2LF4A Series
The 2-1/2” – 12” Double Check Detector Assembly shall be an Apollo Model DCDALF 4A or DCDA2LF 4A. The assembly shall be manufactured in America and carry a 5-year Apollo factory warranty. The TriForce™ center-stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by SS snap-in retainers (2-1/2” – 6”) or SS studs & nuts (8” – 12”). Access to the check valves shall be by an Apollo quick-connect SS coupling (2-1/2” – 6”) or grooved couplings (8” – 12”). The bodies shall be domestic SS in 22-1/2” – 8” sizes and FDA epoxy-coated ductile iron in 10” & 12” sizes. The assembly consists of a mainline double check valve with a Type 2 bypass (Type 1 optional) consisting of a lead free* single check (SCV) and meter bypassing the mainline second check to prevent backflow while accurately measuring all flows up to 2 gpm while the mainline 2nd check remains closed. Assemblies with the optional Type 1 bypass consist of a lead free* double check valve and meter which bypass both mainline checks and accurately meter all flows up to 2 gpm with the mainline checks closed. The Apollo lead free* ball valve test cocks shall have SS handles. The pressure drop across the assembly shall be documented by an independent laboratory. The assembly shall prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are non-health hazards
Double Check Valve - Apollo DCLF 4SG / 4SG / 4S Series
The Apollo DCLF 4SG / 4SG / 4S Series Double
Check Valve is designed to prevent contamination of the potable water supply
due to back-siphonage or backpressure from substances that are non-health
hazards. The modular check valves have replaceable seats and reversible EPDM
seat discs. Grooved connections on an epoxy-coated ductile iron body allow for
easy connection to butterfly valves or gate valves (2-1/2” - 8”), flanged (10”
only).
Reduced
Pressure Detector Assembly - Apollo RPDALF4A / RPDA2LF4A Series
The 2-1/2” – 12” Lead Free Reduced Pressure
Detector Assembly shall be an Apollo Model RPDALF4A or RPDA2LF4A. The assembly
shall be manufactured in America and carry a 5-year Apollo factory warranty.
The TriForceTM center-stem guided check valves shall feature reversible
silicone rubber seat discs. The check valves shall be held in place by SS
snap-in retainers (2-1/2” – 6”) or SS studs & nuts (8” – 12”). Access to
the check valves and relief valve internals shall be by an Apollo quick-connect
SS coupling (2-1/2” – 6”) or grooved couplings (covers) and SS bolts (relief
valves) (8” – 12”). The bodies shall be SS in 2-1/2” – 8” sizes and FDA
epoxy-coated ductile iron in 10” & 12” sizes. The assembly is a mainline RP
with a Type 2 bypass consisting of a lead free* single check valve (SCV) and
meter bypassing the mainline second check to prevent backflow while accurately
measuring all flows up to 2 gpm with the mainline 2nd check remaining closed.
Assemblies with the optional Type 1 bypass consist of a lead free* RP and meter
which bypasses both mainline checks and accurately meters all flows up to 2 gpm
with both mainline checks closed. The Apollo ball valve test cocks shall have
SS handles. Both RP relief valves shall be positioned at the bottom of their
respective assemblies with separate center-access covers. The pressure drop
across the assembly shall be documented by an independent laboratory. The
assembly shall prevent contamination of the potable water supply due to back-siphonage
or back pressure from substances that are health or non-health hazards