High Pressure & Ultra High pressure Tubes
Tubing, Autoclave
Series - 150,000 PSI
Parker Autoclave's high pressure tubing is capable of operating to 150,000 psi (10342 bar) and range in size from 1/4" to 1 " tube size. Tubing is manufactured from cold worked stainless steel.
Parker Autoclave's high
pressure tubing is specifically designed for use with Parker Autoclave’s high
pressure fittings and valves. This unique feature matches the high pressure
tubing to the complete line of fittings and valves provided by Parker Autoclave.
This is not a standard practice in this high pressure industry. The tubing is rated up to 150,000 PSI (10342
BAR). High-pressure tubing is used for specialty fluid handling components in
many industries. This tubing is available in various sizes and pressure ratings
for optimal performance. The high-pressure series uses Parker Autoclave's
Series F high-pressure connection.
Markets:
•
Petrochemical
•
Chemical
•
Research
•
Oil and Gas
Features:
•
Working pressures to 150,000
•
Parker Autoclave Cone and Thread connection used for this tubing
•
Tubing sizes are 1/4", 5/16”,3/8", 9/16", and 1”
•
Tubing is manufactured from cold worked 316 Stainless Steel
•
Operating temperatures from -423ºF (-252ºC ) to 1200ºF (649ºC)
•
Available in special materials
•
Stock tube lengths from 20 to 26.5 foot (6 to 8 meters)
Applications:
•
Fluid Handling Systems
•
High Pressure Gas Systems
•
Research Tanks
Application |
Hydraulic,
Instrumentation, Media Transfer, Suction / Vacuum |
Specifications
Met |
ASTM,
ISO |
Materials
of Construction |
Other
Stainless Steel, Stainless Steel |
Maximum
Operating Pressure |
up
to 10,340 bar, up to 150,000 psi |
Maximum
Operating Temperature |
up
to 650 °C, up to 1200 °F |
Media |
Abrasives,
Adhesives / Glue, Chemical Fluids, Food & Beverages, Fuels, Gases,
Hydraulic Fluids, Medical Fluids, Oil / Petroleum, Pharmaceutical Fluids,
Pneumatic Media, Steam, Water |
Minimum
Operating Temperature |
-70
(and up) °C, -94 and up °F |
Outside
Diameter |
1/2
to 3/4 inch, 1/4 to 1/2 inch, 3/4 to 1 inch |
Maximum
Tube Outside Diameter |
6.35
, 7.94 , 9.53 , 14.29 , 25.4 mm |
Maximum
Tube Inside Diameter |
2.11
, 1.157 , 3.18 , 4.78 , 6.35 , 7.92 , 11.13 mm |
Tube
Wall Thickness |
0.083,
0.125, 0.187, 0.156, 0,125, 0.281 inch, 2.11
, 3.18 , 4.75 , 3.96 , 7.14 mm |
Flow
Area |
0.005,
0.012, 0.028, 0.033, 0.048, 0.076, 0.151 inch2, 3.23
mm², 1.94 mm², 7.74 mm², 18.06 mm², 30.97 mm² , 0.076 in² , 97.42 mm² inch2 |
Assembly |
Special
Tool Required |
Pressure
Rating |
60,000,
100,000, 150,000, 40,000, 43,000 psi |
FAILURE OR IMPROPER
SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN
CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other
information from Parker-Hannifin Corporation, its subsidiaries and authorized
distributors provide product or system options for further investigation by
users having technical expertise. The user, through its own analysis and
testing, is solely responsible for making the final selection of the system and
components and assuring that all performance, endurance, maintenance, safety
and warning requirements of the application are met. The user must analyze all
aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in
any other materials provided from Parker or its subsidiaries or authorized
distributors. To the extent that Parker or its subsidiaries or authorized
distributors provide component or system options based upon data or
specifications provided by the user, the user is responsible for determining
that such data and specifications are suitable and sufficient for all
applications and reasonably foreseeable uses of the components or systems.
Tubing, Autoclave
Series - 150,000 PSI
Parker Autoclave's high pressure tubing is capable of operating to 150,000 psi (10342 bar) and range in size from 1/4" to 1 " tube size. Tubing is manufactured from cold worked stainless steel.
Parker Autoclave's high
pressure tubing is specifically designed for use with Parker Autoclave’s high
pressure fittings and valves. This unique feature matches the high pressure
tubing to the complete line of fittings and valves provided by Parker Autoclave.
This is not a standard practice in this high pressure industry. The tubing is rated up to 150,000 PSI (10342
BAR). High-pressure tubing is used for specialty fluid handling components in
many industries. This tubing is available in various sizes and pressure ratings
for optimal performance. The high-pressure series uses Parker Autoclave's
Series F high-pressure connection.
Markets:
•
Petrochemical
•
Chemical
•
Research
•
Oil and Gas
Features:
•
Working pressures to 150,000
•
Parker Autoclave Cone and Thread connection used for this tubing
•
Tubing sizes are 1/4", 5/16”,3/8", 9/16", and 1”
•
Tubing is manufactured from cold worked 316 Stainless Steel
•
Operating temperatures from -423ºF (-252ºC ) to 1200ºF (649ºC)
•
Available in special materials
•
Stock tube lengths from 20 to 26.5 foot (6 to 8 meters)
Applications:
•
Fluid Handling Systems
•
High Pressure Gas Systems
•
Research Tanks
Application |
Hydraulic,
Instrumentation, Media Transfer, Suction / Vacuum |
Specifications
Met |
ASTM,
ISO |
Materials
of Construction |
Other
Stainless Steel, Stainless Steel |
Maximum
Operating Pressure |
up
to 10,340 bar, up to 150,000 psi |
Maximum
Operating Temperature |
up
to 650 °C, up to 1200 °F |
Media |
Abrasives,
Adhesives / Glue, Chemical Fluids, Food & Beverages, Fuels, Gases,
Hydraulic Fluids, Medical Fluids, Oil / Petroleum, Pharmaceutical Fluids,
Pneumatic Media, Steam, Water |
Minimum
Operating Temperature |
-70
(and up) °C, -94 and up °F |
Outside
Diameter |
1/2
to 3/4 inch, 1/4 to 1/2 inch, 3/4 to 1 inch |
Maximum
Tube Outside Diameter |
6.35
, 7.94 , 9.53 , 14.29 , 25.4 mm |
Maximum
Tube Inside Diameter |
2.11
, 1.157 , 3.18 , 4.78 , 6.35 , 7.92 , 11.13 mm |
Tube
Wall Thickness |
0.083,
0.125, 0.187, 0.156, 0,125, 0.281 inch, 2.11
, 3.18 , 4.75 , 3.96 , 7.14 mm |
Flow
Area |
0.005,
0.012, 0.028, 0.033, 0.048, 0.076, 0.151 inch2, 3.23
mm², 1.94 mm², 7.74 mm², 18.06 mm², 30.97 mm² , 0.076 in² , 97.42 mm² inch2 |
Assembly |
Special
Tool Required |
Pressure
Rating |
60,000,
100,000, 150,000, 40,000, 43,000 psi |
FAILURE OR IMPROPER
SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN
CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other
information from Parker-Hannifin Corporation, its subsidiaries and authorized
distributors provide product or system options for further investigation by
users having technical expertise. The user, through its own analysis and
testing, is solely responsible for making the final selection of the system and
components and assuring that all performance, endurance, maintenance, safety
and warning requirements of the application are met. The user must analyze all
aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in
any other materials provided from Parker or its subsidiaries or authorized
distributors. To the extent that Parker or its subsidiaries or authorized
distributors provide component or system options based upon data or
specifications provided by the user, the user is responsible for determining
that such data and specifications are suitable and sufficient for all
applications and reasonably foreseeable uses of the components or systems.