Login or create an account
CloseReturning Customer
I am a returning customer
Login or create an account
CloseRegister Account
If you already have an account with us, please login at the login form.
Your Account Has Been Created!
Thank you for registering with Welcome to Supertechnical!
You will be notified by e-mail once your account has been activated by the store owner.
If you have ANY questions about the operation of this online shop, please contact the store owner.
Account Logout
You have been logged off your account. It is now safe to leave the computer.
Your shopping cart has been saved, the items inside it will be restored whenever you log back into your account.
Adapters and Couplings
Adapters and Couplings
Cone
and Thread Type Fitting
Parker Autoclave’s Medium and
High pressure line of Adapters and Couplings provide system flexibility by
providing a one piece fitting with two different end connections. The installer
minimizes the number of overall connections.
Product Overview
Parker
Autoclave's Cone and Thread Adapters and Couplings are designed for use with
Parker Autoclave medium and high pressure tubing. These Adapters and Couplings
are rated up from 15,000 PSI (1035 BAR) up to 150,000 PSI (10342 BAR). The male
/female Adapters are designed to adapt a female connec¬tion to another size
and/or type of connection without the need for additional couplings. In
selecting an adapter involving two different sized connections, the larger
connection should be on the male end where it is possible to maximize the
mechani¬cal strength of the adapter.
The Couplings are
manufactured to permit the joining of any combina¬tion of standard size tubing
or tubing and standard pipe with female-to-female couplings. The pressure
rating of Parker Autoclave Couplings is based on the lower rated connection
used.
NOTE: NPT threads
must be sealed using a high quality PTFE tape and/or PTFE paste product. Refer
to thread sealant manufacturer’s instructions on how to apply thread sealant.
Sealing performance may vary based on many factors such as pressure, temperature,
media, thread quality, thread material, proper thread engagement and proper use
of thread sealant. Customer should limit the number of times an NPT fitting is
assembled and disassembled because thread deformation during assembly will
result in
deteriorating seal quality over time. When using only PTFE tape, consider using
thread lubrication to prevent galling of mating parts
Markets: |
Applications |
• Oil and Gas • Petrochemical • Research • Chemical • Power |
• Test Panels • Offshore Skid
Panels • Chemical
Injection • Specialty
High Pressure Gas Systems • Research
Systems |
Features:
• Working
pressures to 150,000 psi (10,342 bar)
• Tubing sizes
are 1/8”, 1/4", 3/8", 5/16”, 9/16", 3/4", and 1-1/2"
• Connections
include Speed Bite, C&T Medium and High Pressure , and NPT
• Weep holes for
safety and leak detection
• Fittings
manufactured from cold worked 316 stainless steel
• Available in
special materials
Tech Specifications
Performance Characteristics
Fitting
Type |
Cone
and Thread |
Connection
1 Size |
1/8",
3/8", 1/2", 1/4", 9/16", 3/4" SpeedBite, Medium
Pressure C&T, High Pressure C&T, Quick Set |
Connection
2 Size |
1/4",
3/8" SpeedBite, Medium Pressure C&T, High Pressure C&T, Quick
Set |
Maximum
Operating Pressure |
15,000,
20,000, 60,000 psi |
Materials
of Construction |
316
Stainless Steel |
Body
Style |
Male/Female
Adapters, Couplings, QSS Male /Female Adapters |
Fitting
Type |
Compression
/ Flareless |
Maximum
Operating Pressure |
15,000,
10,000 psi 1034,
689 bar |
Assembly |
Special
Tool Required |
Connection Type |
W125 , SW250 ,
SW375 , SW500 |
Shape |
Elbow, Tee,
Cross, Straight Coupling , Bulkhead Couplings |
Materials of
Construction |
316 Stainless
Steel |
Maximum Tube
Outside Diameter |
1/8, 1/4, 3/8,
1/2 inch 3.18 , 6 , 10 ,
12.70 mm |
P Series Fittings ( NPT Connections –
15K)
Parker
Autoclave Engineers P Series, Pipe Fittings are designed for liquid and gas
applications. These high quality pipe fittings are available from 1/4" to
1" NPT to 15,000 psi and temperatures to 400°F (204°C)
For
the NPT (Pipe) Connections, the threads must be sealed using a high quality
PTFE tape and/or paste product. Refer to thread sealant manufacturer's
instructions on how to apply thread sealant. Sealing performance may vary based
on many factors such as pressure, temperature, media, thread quality, thread
material, proper thread engagement and proper use of thread sealant.
Customer
should limit the number of times an NPT fitting is assembled and disassembled
because thread deformation during assembly will result in deteriorating seal
quality over time. When using only PTFE tape, consider using thread lubrication
to prevent galling of mating parts.
Markets: |
Applications |
•
Oil and Gas •
Chemical •
Petrochemical |
•
Chemical Injection Skids •
Wellhead Control Panels •
Testing Panels |
Features:
Available
sizes are 1/4", 3/8", 1/2", 3/4" and 1" NPT
Fittings
and tubing manufactured from cold worked 316 stainless steel.
Operating
Temperatures from 0°F (-17.8°C) to 400°F (204°C)
Body
Style - Elbow, Tee, Cross,
Coupling, Bulkhead Coupling, Plug, Street Elbow, Male Elbow, Male Tee, Street
Tee, Male Branch Tee, Hex Close Nipples
Materials - 316 Stainless Steel
Adapters and Couplings
Cone
and Thread Type Fitting
Parker Autoclave’s Medium and
High pressure line of Adapters and Couplings provide system flexibility by
providing a one piece fitting with two different end connections. The installer
minimizes the number of overall connections.
Product Overview
Parker
Autoclave's Cone and Thread Adapters and Couplings are designed for use with
Parker Autoclave medium and high pressure tubing. These Adapters and Couplings
are rated up from 15,000 PSI (1035 BAR) up to 150,000 PSI (10342 BAR). The male
/female Adapters are designed to adapt a female connec¬tion to another size
and/or type of connection without the need for additional couplings. In
selecting an adapter involving two different sized connections, the larger
connection should be on the male end where it is possible to maximize the
mechani¬cal strength of the adapter.
The Couplings are
manufactured to permit the joining of any combina¬tion of standard size tubing
or tubing and standard pipe with female-to-female couplings. The pressure
rating of Parker Autoclave Couplings is based on the lower rated connection
used.
NOTE: NPT threads
must be sealed using a high quality PTFE tape and/or PTFE paste product. Refer
to thread sealant manufacturer’s instructions on how to apply thread sealant.
Sealing performance may vary based on many factors such as pressure, temperature,
media, thread quality, thread material, proper thread engagement and proper use
of thread sealant. Customer should limit the number of times an NPT fitting is
assembled and disassembled because thread deformation during assembly will
result in
deteriorating seal quality over time. When using only PTFE tape, consider using
thread lubrication to prevent galling of mating parts
Markets: |
Applications |
• Oil and Gas • Petrochemical • Research • Chemical • Power |
• Test Panels • Offshore Skid
Panels • Chemical
Injection • Specialty
High Pressure Gas Systems • Research
Systems |
Features:
• Working
pressures to 150,000 psi (10,342 bar)
• Tubing sizes
are 1/8”, 1/4", 3/8", 5/16”, 9/16", 3/4", and 1-1/2"
• Connections
include Speed Bite, C&T Medium and High Pressure , and NPT
• Weep holes for
safety and leak detection
• Fittings
manufactured from cold worked 316 stainless steel
• Available in
special materials
Tech Specifications
Performance Characteristics
Fitting
Type |
Cone
and Thread |
Connection
1 Size |
1/8",
3/8", 1/2", 1/4", 9/16", 3/4" SpeedBite, Medium
Pressure C&T, High Pressure C&T, Quick Set |
Connection
2 Size |
1/4",
3/8" SpeedBite, Medium Pressure C&T, High Pressure C&T, Quick
Set |
Maximum
Operating Pressure |
15,000,
20,000, 60,000 psi |
Materials
of Construction |
316
Stainless Steel |
Body
Style |
Male/Female
Adapters, Couplings, QSS Male /Female Adapters |
Fitting
Type |
Compression
/ Flareless |
Maximum
Operating Pressure |
15,000,
10,000 psi 1034,
689 bar |
Assembly |
Special
Tool Required |
Connection Type |
W125 , SW250 ,
SW375 , SW500 |
Shape |
Elbow, Tee,
Cross, Straight Coupling , Bulkhead Couplings |
Materials of
Construction |
316 Stainless
Steel |
Maximum Tube
Outside Diameter |
1/8, 1/4, 3/8,
1/2 inch 3.18 , 6 , 10 ,
12.70 mm |
P Series Fittings ( NPT Connections –
15K)
Parker
Autoclave Engineers P Series, Pipe Fittings are designed for liquid and gas
applications. These high quality pipe fittings are available from 1/4" to
1" NPT to 15,000 psi and temperatures to 400°F (204°C)
For
the NPT (Pipe) Connections, the threads must be sealed using a high quality
PTFE tape and/or paste product. Refer to thread sealant manufacturer's
instructions on how to apply thread sealant. Sealing performance may vary based
on many factors such as pressure, temperature, media, thread quality, thread
material, proper thread engagement and proper use of thread sealant.
Customer
should limit the number of times an NPT fitting is assembled and disassembled
because thread deformation during assembly will result in deteriorating seal
quality over time. When using only PTFE tape, consider using thread lubrication
to prevent galling of mating parts.
Markets: |
Applications |
•
Oil and Gas •
Chemical •
Petrochemical |
•
Chemical Injection Skids •
Wellhead Control Panels •
Testing Panels |
Features:
Available
sizes are 1/4", 3/8", 1/2", 3/4" and 1" NPT
Fittings
and tubing manufactured from cold worked 316 stainless steel.
Operating
Temperatures from 0°F (-17.8°C) to 400°F (204°C)
Body
Style - Elbow, Tee, Cross,
Coupling, Bulkhead Coupling, Plug, Street Elbow, Male Elbow, Male Tee, Street
Tee, Male Branch Tee, Hex Close Nipples
Materials - 316 Stainless Steel